King air

 

1. Fwd Rh FSB inop, check bulbs.

2. Aft FSB/NS at left bulkhead inop, there is no connector accessible at the aft bulkhead location.

3. 2 cabin window eschusion wire harness are trapped behind window line, connector not accessible.

4. 2 switches fwd left galley inop. not labeled

5. Toilet timer inop? toilet flush motor only runs when button is held down.  Check for delay relay.

6. Aft Rh pylon, 2nd from bottom shelf release broken

 

OVERLAYS

 

101-364? FIREWALL SO VALVE

Clean overlay using plastic cleaner.

Touch up light spills with SemiFlat blac paint, and or Sharpie.

 

est bulbs

Ops test good.

 

101320-299. COPILOT AIR

Clean overlay using plastic cleaner.

Touch up light spills with SemiFlat blac paint, and or Sharpie.

est bulbs

Ops test good

101-32046 DEFROST AIR

Clean overlay using plastic cleaner.

Touch up light spills with SemiFlat blac paint, and or Sharpie.

Test bulbs.  Fould 1 14 volt bulb installed, replaced with new D158-100-5.

Two bulbs inop.  Replace with new.

Noted power connector intermitant.  Boken solder at center conductor.  Resoldered.

 

Ops test good

101-525312-1. ELEVATOR TAB

Clean overlay using plastic cleaner.

Touch up light spills with SemiFlat blac paint, and or Sharpie.

Test bulbs.  4 14 volt bulbs installed.  3 failed bulbs. Replace with new.

Ops test good

101 320252-1. AVIONICS MASTER

 

Clean overlay using plastic cleaner.

Touch up light spills with SemiFlat blac paint, and or Sharpie.

Test bulbs.  2 14 volt bulbs installed.  2 failed bulbs. Replace with new.

Ops test good

PM ? 3 21/4 GAGES

 

Clean overlay using plastic cleaner.

Touch up light spills with SemiFlat blac paint, and or Sharpie.

Test bulbs.  114 volt bulbs installed.  1  failed bulbs. Replace with new.

Ops test good