Steve’s floor

1 gal. Etch and Clean for Concrete in 4:1 Concentrated

 

 

 

 

80×80 is 6400
225 sq ft  per gallon 28 gallons
6 pails, 5 gallons each

Single coat suggested, but video shows 2 coats

does not mention acid prep

This guy uses a sprayer for large area

 

Common sense fellow

 

 

 

Lights at ceiba

 

Round 480 LED

33,600 Lumens, 240W, 5000K, UFO LED High Bay Sensor Ready Light Fixture, 1000W MH Equal, Black Finish, 277-480V, PLT-12692 | 1000Bulbs.com
https://www.1000bulbs.com/product/226812/PLT-12692.html

 

 

 

 

Lift at Cieba

 

Working:

East/west trolly.  Up down lift. One direction has jog movement.

Failed:

1. Latching power enable relay must be manually pushed to engage any power.  No wire on the pendant will engage the power enable relay.  The relay can be relaxed by the key switch.

2.  No travel north/south despite much effort.  The north motor has been replaced, and wires look bad.

3. Only the south motor will click.  Possibly brake releasing, but no motion.

4. Fast jog only works in south direction.

5. Need spare fuses pn ZLP-CC-1 slow blow fuse.

6. Hoist limit switches unserviciable.  Uplimit dancer arm has no affect on hoist travel.

 

 

George’s Crane Service.   (786) 472-8405

 

 

 

 

 

 

 

 

005-1053-sbp2-pendant-install-manual-print-06-10-2020-2up-no-crops

 

 

 

 

 

Slow blow fuse

New OEM LP-CC-1 LP-CC-1A LP-CC 1A 600Vac Time Delay Fuse, Pack of 10 https://a.co/d/cgZP0Yt

 

 

   

 

 

 

 

 

 

G100 squawks

 

 

1 each grey wick failed, Dayton pn dg16785, model 51cd2a

Rh winglet angled wick failed. no p/n

Damage at RH stab tip. Bonging Foil peeled up.

One black wick failed.   HR SMITH PN10-900-25

RH elevator bonding over 3 ohms.  Clean bonding straps.

Lubricate pilot and copilot stow-able arm rests.

Fwd rh galley, one drawer does not latch.

FSB/NS CB pops. Done

FIRE TEST erratic, sometimes only some lights will test. Failed test sw p/n 25W847009….. 9 is obscure.  video

https://youtube.com/shorts/Fy3L2XfmvWo?si=h9YSwtJY1g_Bx4-q

 

Bolt stripped at lower left APU REGULATOR computer mount.   Needs a new floater

Entertainment inop.  No wire diagrams at all.   None! Not any !   402 479 4221 ex.   Mellisa.

https://www.manualslib.com/manual/3049710/Flight-Display-Systems-Fd200cpu-7.html?page=12#manual

MASTER CAUTION , no DIM mode, task 311220

FMS displays FAA n number on powwr up.  Configured #1 and #2 FMS to display current aircraft registration at power up.

Passenger monitor droops 5 degrees in extended position.

Rubber trim channel at edges of peistal dis-bonded.  Remove, clean old glue, reapply.

 

Plastic catch-all aft of pedistal broken, trim disbonded.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

online white board

https://lucid.app/lucidspark/1fd14493-e650-4a39-8b33-22b7fbdab13c/edit?invitationId=inv_ee803a74-085b-4257-9c33-e4c5fa871c28

ZITEBOARD src=https://lucid.app/lucidspark/1fd14493-e650-4a39-8b33-22b7fbdab13c/edit?invitationId=inv_ee803a74-085b-4257-9c33-e4c5fa871c28

src=https://lucid.app/lucidspark/1fd14493-e650-4a39-8b33-22b7fbdab13c/edit?invitationId=inv_ee803a74-085b-4257-9c33-e4c5fa871c28

https://lucid.app/lucidspark/1fd14493-e650-4a39-8b33-22b7fbdab13c/edit?invitationId=inv_ee803a74-085b-4257-9c33-e4c5fa871c28&page=0_0#

 

example of a board

online white board

https://lucid.app/lucidspark/1fd14493-e650-4a39-8b33-22b7fbdab13c/edit?invitationId=inv_ee803a74-085b-4257-9c33-e4c5fa871c28

 

another one for wordpress

Ziteboard Online Whiteboard